Determination of the activity ratios of 231Pa to 235U and 227Th to 235U in ore samples using gamma-spectrometry
dc.contributor.author | Rekha, A. K. | |
dc.contributor.author | Dingankar, M. V. | |
dc.contributor.author | Anilkumar, S. | |
dc.contributor.author | Narayani, K. | |
dc.contributor.author | Sharma, D. N. | |
dc.date.accessioned | 2006-10-06T09:42:00Z | |
dc.date.available | 2006-10-06T09:42:00Z | |
dc.date.issued | 2006 | |
dc.format.extent | 5357 bytes | |
dc.format.mimetype | text/html | |
dc.identifier.source | Journal of Radioanalytical and Nuclear Chemistry, Vol. 268, No.3 (2006) p. 453 460 | en |
dc.identifier.uri | http://hdl.handle.net/123456789/96 | |
dc.language.iso | en | en |
dc.subject | 231Pa | en |
dc.subject | 235U | en |
dc.subject | gamma-spectrometry | en |
dc.subject | nuclear fuel cycle | en |
dc.subject | high level waste | en |
dc.subject | chronometer | en |
dc.subject | Thorium ore | en |
dc.subject | 227Th | en |
dc.title | Determination of the activity ratios of 231Pa to 235U and 227Th to 235U in ore samples using gamma-spectrometry | en |
dc.type | Article | en |