Sampling based uncertainty analysis of 10% hot leg break LOCA in large scale test facility
dc.contributor.author | SenGupta, S. | |
dc.contributor.author | Dubey, S. K. | |
dc.contributor.author | Rao, R. S. | |
dc.contributor.author | Gupta, S. K. | |
dc.contributor.author | Rain, V. K. | |
dc.date.accessioned | 2011-06-16T09:04:57Z | |
dc.date.available | 2011-06-16T09:04:57Z | |
dc.date.issued | 2010 | |
dc.format.extent | 4525 bytes | |
dc.format.mimetype | text/html | |
dc.identifier.source | Nuclear Engineering and Technology. Vol. 42 (6): pp. 690-703 | en |
dc.identifier.uri | http://hdl.handle.net/123456789/4897 | |
dc.language.iso | en | en |
dc.subject | Accident Analysis | en |
dc.subject | Latin Hypercube Sampling | en |
dc.subject | LOCA | en |
dc.subject | LSTF | en |
dc.subject | UMAE | en |
dc.subject | Uncertainty | en |
dc.title | Sampling based uncertainty analysis of 10% hot leg break LOCA in large scale test facility | en |
dc.type | Article | en |