The goal of the study is to investigate elemental concentrations and source signatures of particulate matter at a selected receptor site in an urban area Navi Mumbai which is one of the hot spots of India with heavy industrialization. To achieve the objective, particulate matter samples were collected from 2008–2010 using Gent sampler with the automatic dichotomous size segregation unit. It was observed that the three year average concentrations of coarse ((PM10–2.5μm) and fine (PM2.5μm) fractions of PM were 89.92 (μgm–3) and 42.25 (μgm–3) respectively which were higher than the national standards prescribed by Central Pollution Control Board (CPCB), India. Subsequent elemental analysis of air filters using INAA and EDXRF showed marginally higher levels of anthropogenic derived elements. Further more, in the present study potentially contributing sources of coarse and fine PM were identified using two different receptor model techniques Factor Analysis (FA) and Positive Matrix Factorization (PMF). Six possible contributing sources of coarse fraction and seven probable sources of fine PM were identified by both the techniques. Further, sources identified by the receptor techniques and the comparability between the two techniques were also evaluated.