BARC/PUB/2018/0466

 
 

Development of an algorithm to estimate eye lens dose in terms of operational quantity Hp(3) using head tld badge

 
     
 
Author(s)

Madhumita, B.; Sneha, C.; Dipali, V.; Pradhan, S. M.; Bakshi, A. K.; Datta, D.; Tripathi, S. M.; Singh, S. K.
(RP&AD;RSSD)

Source

Radiation Protection Dosimetry, 2018. Vol. 178 (4): pp. 364-373

ABSTRACT

In view of the recommendations of International Commission on Radiological Protection for reduction of the occupational annual dose limit for eye lens from 150 mSv to 20 mSv/y, questions have been raised on the adequacy of monitoring for the quantities Hp(10) and Hp(0.07). As an immediate requirement, in the present situation, where there is no exclusive eye lens dosemeter in India, the existing chest TLD badge was modified to be used as head badge (head dosemeter) by including a strap to enable wearing on the forehead. In order to estimate the eye lens dose in terms of the operational quantity Hp(3), the prevalent algorithm of chest badge was also modified. The modified algorithm was applied to estimate Hp(3) for dosemeters irradiated to various beta and photon radiations including mixtures. The Q values (estimated/delivered dose equivalent) were found to be within ±20% for most of the photon beams.

 
 