BARC/PUB/2022/0367

 
 

Performance of BARC neutron personal dosemeter in eurados intercomparison exercise IC 2017n - a lesson learnt

 
     
 
Author(s)

Bakshi, A. K.; Beck, M.; Shah, P.
(RP&AD)

Source

Radiation Protection Dosimetry, 2022. Vol. 198 (6): pp. 370-377

ABSTRACT

Bhabha Atomic Research Centre (BARC) conducts fast neutron personnel monitoring service to radiation workers involved in reactors, accelerators, spent fuel processing plants, oil-well industries, etc., using CR-39 detector based dosemeter. In this study, performance of the BARC fast neutron personnel dosemeter has been checked through EURADOS intercomparison exercise for simulated work place neutron fields. The overall performance of the dosemeter in the lower dose equivalent (≤ 5 mSv) was found to be acceptable as per ISO-14146. The performance (ratio of estimated to reference dose equivalent) of the dosemeter in the higher dose equivalen t(12 mSv) was found to be in the range of 0.48–0.44 and not satisfactory as per the ISO-14146 criteria for any dosimetry service. Based on this performance, a new imaging system was developed and performance of the dosemeters were improved and found to be acceptable (within ±20%) as per ISO.

 
 