BARC/PUB/2017/0495

 
 

Effect of dynamic bias on accuracy of radioactive particle tracking (RPT) technique at different data acquisition frequencies

 
     
 
Author(s)

Kamalanathan, P.; Kalo, L.; Pant, H. J.; Upadhyay, R. K.
(IP&AD)

Source

Applied Radiation and Isotopes, 2017. Vol. 128: pp. 13-21

ABSTRACT

The accuracy of radioactive particle tracking technique depends on the ability to locate the exact position of a tracer particle. In the current work, experiments are performed to find the accuracy of an RPT measurement in terms of locating the position of the tracer particle and its velocity measurement. Results are presented for different tracer velocities at different data acquisition frequencies to minimize the error generated due to dynamic bias. Finally an optimal frequency is recommended for different velocities of a tracer particle to achieve the best possible accuracy.

 
 