A membrane optode was developed utilizing the 8-hydroxyquinaldine (HQ)
facilitated preconcentration of UO22+ ions and subsequent colored complex
formation of UO2 2+ with 4-(2-thiazolylazo)-resorcinol (TAR) in optode matrix.
The composition of the membrane optode was optimized by scanning several extractants immobilized in different plasticized polymer matrices. It was observed that the chelating agent HQ along with an indicator TAR immobilized in the
tri-(2-ethylhexyl)phosphate (TEHP) plasticized cellulose triacetate matrix (CTA) was best suited as an optode for the
UO2 2+ ions in aqueous samples. On sorption of
UO2 2+ in the optode matrix, TAR changes color of the optode from yellow to magenta having a
maximum absorbance (lmax) at 546 nm. The uptake
of UO2 2+ ions in the optode was found to be
pHdependent and was maximum (>90%) at pH above 3. The acetate buffer (0.1 mol
L−1 sodium acetate + 0.1 mol L−1 acetic acid) was found to be necessary for the stable response. The optimum equilibration time for the optode (2cm×1 cm) was found to be 30 min in 10mL aqueous sample containing acetate buffer (pH 4.75). The equilibration time was found to increase with increase in aqueous sample volume. The optode
response was found to be linear in the UO2 2+
ions concentration range of 0.01–0.11 mmol L−1 in tap water as well as aqueous solutions containing 0.1 mol
L−1 NaCl or NaNO3. The tolerance to the presence of several cations and anions in the determination of
UO2 2+ ion was studied. It was observed that the optode in the presence of buffer can tolerate presence of large amounts of interfering cations
(Ce4+, V4+, Eu3+, Al3+,
Fe3+, Ni2+, Cd2+, Co2+,
Pb2+, Hg2+, Cu2+ and Th4+ ions) without hindering the sorption of
UO2 2+ ions in the optode matrix. The present work indicated that 50 ppb
UO2 2+ ions in 100mL sample can easily be quantified using this optode. The optode was found to be fully reversible, can readily be regenerated by equilibrating it with 0.1 mol
L−1 HNO3 and reusable up to three cycles. The applicability of the developed optode in real samples was studied by determining uranium in the ground water samples spiked with a known quantity of
UO2 2+ ions.
|